1 / 5
| 1000W Series Switching Power Supply with PFC | |
|---|---|
| Model | S-1000P-150V |
| DC output voltage | 150V |
| Output current | 6.7A |
| Output power | 1000W |
| Efficiency (Full load) | 90% |
| Range of voltage regulation |
102-150V
Tip: if the output voltage is lowered, the maximum output current remains unchanged and the output power decreases. (Power= voltage * current)
|
| With Active PFC Power Factor Correction Function | |
| Input voltage | AC 100-240V (50Hz / 60Hz) |
| Power factor(PF) | PF value > 0.99 (at 100% full load) |
| Fan failure protection | Either of the two cooling fans does not rotate or the fan is not detected, and the power supply has no output voltage. |
| Over load protection | The overload protection mode is constant current limiting mode, which limits the output current value to remain unchanged and does not cause over-current output. The output voltage decreases as the load increases. |
| Overheat protection | When the internal temperature is too high, activate the overheat protection, turn off the output voltage, and automatically recover after the temperature drops. |
| Short Circuit Protection |
• Short time instantaneous short circuit: turn off the output and automatically recover after 3 seconds • Long term continuous short circuit: turn off the output, automatically restart once every 3 seconds (burping mode) |
| Output overvoltage protection | The overvoltage point is 130% of the nominal voltage value. After overvoltage, the output is turned off and will not automatically recover. You need to turn off the power and power it back on to recover. |
| Under voltage protect | The AC input voltage is below 96V, and the power supply cannot be used |
| Heat dissipation | Temperature controlled automatic speed regulation fan (internal blowing mode, 2 fans) |
| Net Weight | 1.4kg |
| Dimensions | 268 mm *131 mm *41mm (L* W* H) |